AutoLab TF Dispenser Technical Manual – Revision 5
AutoLab TF dispensers Technical Manual TFTMTF / Rev 5.0 / 24
th
May 2006 Page 54 of 150
2-3-6 AutoLab TF-120/160 Output Definitions
WIRE
NO.
OUTPUT BIT NO.
OF LA50B DIO
NAME
CONTROL
DEVICE
EXPLAINATION AutoLab
TF-120/160
000 0 / 0 DIO0 Grab hand Air valve Grabbing Injectors.
001 1 / 0 DIO0 Dispense head up/down Air valve
Moving dispense head
up/down.
002 2 / 0 DIO0 Anti-drip plate Air valve
Moving anti-drip plate
in/out.
003 3 / 0 DIO0
A zone
Tray up/down
Air valve
Moving dye pot adapter
up/down.
004 4 / 0 DIO0
A zone Inlet Air valve
Inlet dye pot to scale or
Aux. position.
005 5 / 0 DIO0
A zone
Aux. dispense head A
Valve
Aux. dispenses head
moves front, middle, back
for Aux. dispense.
006 6 / 0 DIO0
A zone
Aux. dispense head B
Valve
Aux. dispense head
moves front, middle, back
for Aux. dispense.
007 7 / 0 DIO0
A zone
Agitation switch
DS Relay
Board
Switch the A zone
agitation on/off.
008 8 / 0 DIO0
A zone
Agitation direction
DS Relay
Board
Control A zone agitation
direction.
(clockwise/anti-clockwis
e).
009 9 / 0 DIO0
A zone
Water dispense valve A
Water valve
Open/close A zone
water dispensing valve
A.
010 10 / 0 DIO0
A zone
Water dispense valve B
Water valve
Open/close A zone
water dispensing valve
B.
011 11 / 0 DIO0
A zone
Water dispense valve C
Water valve
Open/close A zone
water dispensing valve
C.
012 12 / 0 DIO0
B zone
Agitation switch
DS Relay
Board
Switch the B zone
agitation on/off.
013 13 / 0 DIO0
A zone
ACK confirm button
Push Button
Push the button when
to start dispensing, and
it flash in dispensing
014 14 / 0 DIO0 Alarm Alarm Alarm。
015 15 / 0 DIO0
B zone
Agitation direction
DS Relay
Board
Control B zone agitation
direction.
(clockwise/anti-clockwis
e)
019 3 / 1 DIO1
B zone
tray up/down
Air valve
Dye pot up/down
weighing.
020 4 / 1 DIO1 B zone Inlet Air valve
Inlet dye pot to scale or
Aux. position.
021 5 / 1 DIO1 B zone aux. dispense head A Air valve
Aux. dispenses head
moves front, middle,
back for Aux. dispense.
022 6 / 1 DIO1 B zone aux. dispense head B Valve
Aux. dispenses head
moves front, middle,
back for Aux. dispense.
023 7 / 1 DIO1
C zone
Agitation switch
DS Relay
Board
Switch the C zone
agitation on/off.
024 8 / 1 DIO1
C zone
Agitation direction
DS Relay
Board
Control C zone agitation
direction.