1D Symbologies Enter/Exit Programming Mode
Product Reference Guide 189
Code 11 Set Length 2
This feature specifies one of the bar code lengths for Code 11 Length Control 
on page 187
. Length 2 is the maximum label length if in Variable Length on 
page 187
 Mode, or the second fi
xed length if in 
Fixed Length on page 187 
Mode. Length includes the bar cod
e’s check and data characters.
The length can be set from 2 to 50 characters. A setting of 00 specifies to 
ignore this length (only one fixed length). See 
"Set Length 2" on
 page 303 for 
more detailed progr
amming instructions.
Select Code 11 Length 2 Setting
To configure this feature, scan the ENTER/EXIT bar code 
above, then the bar code at left followed by digits from 
the Alphanumeric characters in 
Appendix D, Key-
pad
 representing your desired character(s). End by 
scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and 
not save 
the entry string. You can then start again at the 
beginning.
CANCEL
DEFAULT
50 = Length 2 is 50 Characters
$CC1L2
~