Product Reference Guide 91
Chapter 10
Wand Emulation Interface
Introduction
This chapter provides feature/settings configuration for the Wand Emulation interface.
Wand Emulation Standard Factory Settings
Reference Appendix B, Standard Defaults for a listing of standard factory settings.
Wand Idle State
This feature specifies the level of the Wand output signal when the reader is idle.
NOTE
TTL logic levels:
0V <= Low <= 0.7V
2.4V <= High <= 5.25V
ENTER/EXIT PROGRAMMING MODE
Wand Idle State = Low
Wand Idle State = High
DEFAULT