Figure 32. Installing cooling fan
Next steps
1 Install the internal riser.
2 Install the cooling shroud.
3 Follow the procedure listed in After working inside your system.
Intrusion switch
The Chassis Intrusion Switch is activated when the cover of your system is removed while your system is on. The system event logs [SEL]
records the number of times the cover is removed when the system is turned on..
Removing the intrusion switch
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
NOTE
: Ensure that you note the routing of the cables as you remove them from the system board. You must route the
cables properly when you replace them to prevent the cables from being pinched or crimped.
3 Remove the air shroud.
4 Remove internal MiniPERC riser.
Steps
1 Disconnect the intrusion switch cable connected to the system board.
2 Slide the intrusion switch out of the intrusion switch slot.
Installing and removing system components
73