434 Viewing Statistics
Modifying an Alarm Table Entry
1
Open the
RMON Alarms
page.
2
Select an entry in the
Alarm Entry
drop-down menu.
3
Modify the fields.
4
Click
Apply Changes
.
The entry is modified, and the device is updated.
Displaying the Alarm Table
1
Open the
RMON Alarms
page.
2
Click
Show All
.
The
Alarms Table
opens.
Deleting an Alarm Table Entry
1
Open the
RMON Alarms
page.
2
Select an entry in the
Alarm Entry
drop-down menu.
3
Check the
Remove
check box.
4
Click
Apply Changes
.
The entry is deleted, and the device is updated.
Defining Device Alarms Using the CLI Commands
The following table contains the CLI commands for defining device alarms.
Table 8-10. Device Alarm CLI Commands
CLI Command Description
rmon alarm
index MIB_Object_ID interval
rthreshold fthreshold revent fevent
[type
type
] [startup
direction
] [owner
name
]
Configures RMON alarm conditions.
show rmon alarm-table Displays summary of the alarm table.
show rmon alarm Displays the RMON alarm configuration.