Table 126. Status LED indicators and descriptions (continued)
Icon Description Condition Corrective action
temperature is out of range or
there is a fan failure).
● System cover, air shroud,
or back filler bracket is
removed.
● Ambient temperature is
too high.
● External airflow is
obstructed.
If the problem persists, see
the
Getting help section.
Electrical indicator The indicator turns solid
amber if the system
experiences an electrical error
(for example, voltage out
of range, or a failed power
supply unit (PSU) or voltage
regulator).
Check the System Event Log
or system messages for the
specific issue. If it is due to a
problem with the PSU, check
the LED on the PSU. Reseat
the PSU.
If the problem persists, see
the
Getting help section.
Memory indicator The indicator turns solid
amber if a memory error
occurs.
Check the System Event Log
or system messages for the
location of the failed memory.
Reseat the memory module.
If the problem persists, see
the
Getting help section.
PCIe indicator The indicator turns solid
amber if a PCIe card
experiences an error.
Restart the system. Update
any required drivers for the
PCIe card. Reinstall the card.
If the problem persists, see
the
Getting help section.
NOTE: For more
information about the
supported PCIe cards,
see the Expansion card
installation guidelines
section.
System health and system ID indicator codes
The system health and system ID indicator is located on the left control panel of the system.
Figure 207. System health and system ID indicator
System diagnostics and indicator codes
243