SM200 and ThetaProbes Moisture Meter User Manual 4.0
Field Capacity
Sets the Field Capacity, used for mm Deficit calculations.
Options: 0 to 1 Default: 0.38 Units: m
3
.m
-3
If you want mm Deficit you must define the Field Capacity (and Root Depth in the
Options, Data menu). We provide a table for Mineral soils on page 106. Organic
soils are so variable you have to determine field capacity experimentally, before it
makes any sense to take mm Deficit readings - see "Calculating Field Capacity" on
page 108.
Press Set to select Options, Soil Set-Up menu.
Scroll through the Soil names, choose one, pressing Set:.
Select Capacity.
Scroll to select the actual field capacity.
Press Set to select it.
Note : A negative "mm Deficit" result indicates you set the Field Capacity too low.
Display Units Options
Selects the units in which new readings are to be displayed and stored.
m
3
.m
-3
Volumetric moisture content in cubic metres of
water per cubic metre of soil
Volumetric water content as a percentage
Soil moisture deficit in mm.
Sensor output in milliVolts.
Soil moisture deficit in mm
Volumetric water content in m
Soil moisture deficit in mm
Volumetric water content in m
Volumetric water content in m
3
.m
-3
Sensor output in milliVolts
Sensor output in milliVolts.
Soil moisture deficit in mm
Sensor output in milliVolts.
Warning: Use of the HH2 default value for Field Capacity may not give meaningful
results because it may not represent a common soil type.
Select the Options, Display menu.
Scroll through the following options and press Set to select one.