SM200 and ThetaProbes
25
Reading the sensor
Before Taking Readings
1. Set the Device to SM200, ML1 or ML2.
2. Select the Plot ID, Device ID, Root Depth and Sensor Depth (all optional).
3. Set the Field Capacity (Soil Set-Up menu) if you want soil moisture deficit.
4. Set the Sample number (optional, it auto increments).
5. Set the Display.
6. Set the Date and Time if you have not done so for a few weeks.
7. Connect the HH2 to the sensor.
To take Readings
1. Press Read
If successful the meter displays the reading, e.g.-
ML2 Store?
32.2%vol
2. Scroll to view the other readings.
3. Press Store to save the readings, or press Esc.
4. Press Read for the next reading.