EasyManua.ls Logo

Delta VFD-MS300 - Warnings and Error Codes for VFD Indicators; Troubleshooting

Delta VFD-MS300
61 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VFD-MS300/MH300 EtherNet/IP Communication Card CMM-EIP01
CMM-EIP01 Operation Manual
54
8.2 Warnings and Error Codes for VFD Indicators
ID Code Description
75
ECFF Manufacturing parameter read error
76
ECiF Internal parameter configured incorrectly
80
ECEF EtherNet connection error
81
ECto
Communication timeout between CMM-EIP01 and
VFD-MS300/MH300
82
ECCS
Checksum error in the communication between CMM-EIP01 and
VFD-MS300/MH300
83
ECrF The CMM-EIP01 has been restored to its factory default settings
85
ECo1 Exceeds the max. number of connections in EtherNet/IP
86
ECiP IP error
87
EC3F Mail alarm
8.3 Troubleshooting
Problem Cause of the problem Troubleshooting instructions
Power indicator is
off
AC drive is not connected to a
power source
Check if the AC drive is powered and whether its
power supply is working properly.
CMM-EIP01 is not connected
to the AC drive
Check if the CMM-EIP01 is tightly connected to
the AC drive
Link indicator is off
CMM-EIP01 is not connected
to a network
Check to see if the network cable is properly
connected to the network
RJ-45 connector is not
connected properly
Check if the RJ-45 connector is attached to the
EtherNet port correctly
Unable to locate
the communication
card
CMM-EIP01 is not connected
to a network
Check to see if CMM-EIP01 is properly
connected to a network
The computer and CMM-EIP01
are on different networks,
blocked by a firewall
Search by using a designated IP address or
modify settings with the keypad
Unable to open
CMM-EIP01 setup
page
CMM-EIP01 is not connected
to a network
Check to see if CMM-EIP01 is properly
connected to a network
Incorrect communication
settings in DCISoft
Make sure the communication setting in DCISoft
is set to EtherNet
The computer and CMM-EIP01
are on different networks,
blocked by a firewall
Conduct setup via the keypad on the AC drive
Can open
CMM-EIP01's
setup page but
cannot use
webpage
monitoring
Incorrect network settings for
CMM-EIP01
Check if the network settings for CMM-EIP01 are
correct. Please consult an IT administrator if you
are on your company's Intranet. For home
networks, refer to the instructions for network
settings provided by your internet service
provider (ISP).
Unable to send
e-mails
Incorrect network settings for
CMM-EIP01
Check if the network configurations for
CMM-EIP01 are correct
Incorrect mail server settings Check SMTP server's IP address

Table of Contents