5.2 Data Exchange via I/O Connection Implicit Message
The host controller is used to designate the configurations of read / write data
addresses via the mapped registers of the EIP communication card. The mapped registers
are then used to perform a one-time read/write of fixed-sized address data. Currently, the
Object Class that supports Implicit Messages has the following address and definitions:
Implicit Message
fixed address
definitions Name
Function Object Instance Attributes Size Description
Connection 1
(v1.06 or above)
Input
0x04
0x69
0x03 32 words
Corresponds to data in the input
buffer register
0x04 1 word
Corresponds to the length of input
buffer register
Output 0x68
0x03 32 words
Corresponds to data in the output
buffer register
0x04 1 word
Corresponds to the length of
output buffer register
Configuration 0x80
0x03 128 words
Corresponds to the address and
data of setup component
0x04 1 word
Corresponds to the length of the
setup component
Connection 1_
Listen only
(v1.06 or above)
Input 0x69
0x03 32 words
Corresponds to the input buffer
register
0x04 1 word
Corresponds to the length of input
buffer register
Output 0xC7
0x03 0 words
0x04 0 words
Configuration 0x80
0x03 128 words
Corresponds to the address and
data of setup component
0x04 1 word
Corresponds to the length of the
setup component
Connection 2
Input 0x65
0x03 16 words
Corresponds to the input buffer
register
0x04 1 word
Corresponds to the length of input
buffer register
Output 0x64
0x03 3 words
Corresponds to the output buffer
register
0x04 1 word
Corresponds to the length of
output buffer register
Configuration 0x66
0x03 64words
Corresponds to the address and
data of setup component
0x04 1words
Corresponds to the setup
component
Connection 2_
Listen only
Input 0x65
0x03 16 words
Corresponds to data in the output
buffer register
0x04 1 word
Corresponds to the length of
output buffer register
Output 0xC7
0x03 0 words
0x04 0 words
Configuration 0x66
0x03 0 words
0x04 0 words

Table of Contents