Chapter 4 Parameters|VFD-VL
4-44
Frequency
Output
Multi-function
Input Terminal
D=41
Frequency
T1<02-36
07-03
07-04
02-31
02-32
T2<02-35
Operation
Command
(FWD/REV)
Time
Multi-function
Output Terminal
D=15
Zero speed
Output
fr eq ue ncy
Operation
command
Magnetic
contactor
Multi -fu nction
input terminal
MI41
Multi-fu nction
input terminal
MI41
Multi -fu nction
input terminal
MI41
Detection time for contactor (02-36)
Status 1
Status 2
Status 3
02-09
Digital Input Response Time
Control
mode
VF VFPG SVC FOCPG TQCPG FOCPM
Factory setting: 0.005
Settings 0.001~ 30.000 sec
This parameter is used for digital input terminal signal delay and confirmation. The delay time
is confirmation time to prevent some uncertain interferences that would result in error (except
for the counter input) in the input of the digital terminals (FWD, REV and MI1~8). Under this
condition, confirmation for this parameter could be improved effectively, but the response time
will be somewhat delayed.