C.1 Capacity Formulas
1. When one AC motor drive operates one motor
The starting capacity should be less than 1.5x rated capacity of AC motor drive
The starting capacity=
)(_____5.1
375cos973
2
kVAdrivemotorACofcapacitythe
t
NGD
T
Nk
A
L
×
×+
××
×
ϕη
2. When one AC motor drive operates more than one motor
2.1 The starting capacity should be less than the rated capacity of AC motor drive
Acceleration time
60 seconds
The starting capacity=
()
[]
()
)(_____5.11
cos
111 kVAdrivemotorACofcapacitythek
n
n
Pknn
Nk
sCss
T
s
T
×+=+
×
×
ϕη
Acceleration time
60 seconds
The starting capacity=
()
[]
()
)(_____1
cos
111 kVAdrivemotorACofcapacitythek
n
n
Pknn
Nk
sCss
T
s
T
+=+
×
×
ϕη
2.2 The current should be less than the rated current of AC motor drive(A)
Acceleration time
60 seconds
)(______5.111 AdrivemotorACofcurrentratedthek
n
n
In
SM
T
S
T
×++
Acceleration time
60 seconds
)(______11 AdrivemotorACofcurrentratedthek
n
n
In
SM
T
S
T
++
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD-VL Series and is the answer not in the manual?

Delta VFD-VL Series Specifications

General IconGeneral
BrandDelta
ModelVFD-VL Series
CategoryDC Drives
LanguageEnglish

Related product manuals