Chapter 4 Parameters|VFD-VL
4-112
These two parameters are used to decide width of slope of ASR command during zero speed
to low speed or Pr.10-17 to high speed.
10-17
10- 13
10- 14
10-15
10-16
Hz
PI
10-11
10-12
0Hz
10-20
10-21
10-22
Zero Speed Position Holding Time
Control
mode
FOCPM
Factory Setting: 0.250
Settings 0.001 to 65.535sec
10-23
Filter Time at Zero Speed
Control
mode
FOCPM
Factory Setting: 0.004
Settings 0.001 to 65.535sec
10-24
Time for Executing Zero Speed
Control
mode
FOCPM
Factory Setting: 0
Settings 0 After the brake release set in Pr.02-29
1 After the brake signal input (Pr.02-01~02-08 is set to 42)
When Pr.10-24=0, the zero speed control needs to be used with Pr.02-29. (refer to the
explanations in Pr.02-32)
10-25
Elevator Leveling (Zero Speed Gain P)
Control
mode
VF VFPG SVC FOCPG FOCPM
Factory Setting: 0
Settings 0~1000.0%
10-26
Elevator Leveling (Zero Speed Integral I)
Control
mode
VF VFPG SVC FOCPG FOCPM
Factory Setting: 0
Settings 0~10.000 sec