EasyManua.ls Logo

DENTSPLY MULTIMAT Touch - Setting Vacuum Level; Setting Heat Rate; Setting High Temperature; Setting Vacuum Time

DENTSPLY MULTIMAT Touch
57 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30
Press the yellow touch button. The current value flashes. Use the numeric keypad 0-9 to
enter, for example the value 0300 to have 3 minutes.
5.5.5 Setting Vacuum level
Press the respective yellow touch button. Use the numeric keypad 0-9 to enter the value 50.
Select the vacuum unit in the "Basic Set-Up" section.
In Ceramco firing mode, the vacuum level can be activated or deactivated in a temperature-
controlled fashion.
5.5.6 Setting Heat rate
Press the respective yellow touch button. Use the numeric keypad 0-9 to enter for example
the value 80 for setting the increase rate on 80° C / Minute. With other firing procedures, the
rate of temperature rise can be time-controlled.
5.5.7 Setting High temperature
Press the respective yellow touch button. Use the numeric keypad 0-9 to enter for example
the value 940.
5.5.8 Setting Vacuum time
a) time controlled (e.g. Dentsply DeTrey Mode)
Press the respective yellow touch button. Use the numeric keypad 0-9 to enter for example
the value 0100 for 1 minute.
b) temperature controlled (e.g. Dentsply Ceramco Mode)
Press the according yellow sensor button. Use the numeric keypad to enter activation and
deactivation temperature for your vacuum.
Note: The ceramic types, metal ceramics and pressable ceramics are entered and shown in
minutes:seconds, sinter ceramics in hours:minutes.
5.5.9 Setting Firing time
Press the respective yellow touch button. Use the numeric keypad 0-9 to enter for example
the value 0200 for 2 minutes.
Note: The ceramic types metal ceramics and press ceramics are entered and shown in
minutes : seconds, sinter ceramics in hours : minutes.
5.5.10 Setting Tempering temperature
Tempering will increase the thermal expansion coefficient of the ceramics by a controlled
growth of Leucite crystals. In this way, the thermal expansion coefficient for metal ceramics
can be adjusted to alloys which deviate significantly in terms of their thermal expansion
coefficient. Touch the yellow sensor next to the text and enter for example the figure 1000 for
1000°C.
Consult ceramic’s manufacturer before use!
5.5.11 Setting the tempering time
Touch the yellow sensor and enter for example the figure 1000 in the numeric keypad for 10
minutes for example.

Table of Contents