49
9. Preset programs
9.1 Firing Table for Ceramco 3- Metal Ceramics (DeTrey Mode)
(Use honey comb)
Prog
No.
Cycle Preheat
Temp.
°C
Drying
time
(min)
Preheat
min.
Vacuum
Level
hPa
Heating
rate
(hPa)
Firing/
Temp.
(°C)
Vacuum
holding
time
(min)
Firing
time
min.
Cooling
stage
302 D-C3
Paste opaque
500 05:00 03:00 50 100 975 00:00 00:00 0
303 D-C3
Powder
opaque
650 05:00 05:00 50 70 965 00:00 00:00 0
304 D-C3 Margin 650 05:00 05:00 50 70 965 00:00 00:00 0
305 D-C3-
Opaque
dentine/
Dentine effect/
Dentine
enamel
650 05:00 05:00 50 45 930 00:00 01:00 0
306 D-C3
Glaze w/o
Glaze liquid
650 03:00 03:00 0 45 920 00:00 03:00 0
307 D-C3-
Glaze with
Glaze liquid
650 03:00 03:00 0 55 925 00:00 0:30 0
308 D-C3-
Correction
(Add-On)
650 05:00 05:00 50 55 920 00:00 0:00 0
D = DeTrey Modus
C3 = Ceramco 3 – Metal bonding ceramic
These firing temperatures are recommended figures. If necessary, carry out a firing test, and
adjust firing temperatures or times.
Incase of firing a larger number of objects it may be necessary to adjust the firing
temperature or the holding time.