EasyManua.ls Logo

Digi IX10

Digi IX10
996 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Serial port Configure Remote Access mode
IX10 User Guide
197
a. (Optional) Enable monitoring of CTS (Clear to Send) changes on this port:
(config)>serial port1 monitor cts true
(config)
b. (Optional) Enable monitoring of DCD (Data Carrier Detect) changes on this port:
(config)>serial port1 monitor dcd true
(config)
14. (Optional) Configure autoconnect:
a. Enable autoconnect:
(config)>serial port1 autoconnect enable true
(config)>
b. Set the option that will trigger the connection:
(config)>serial port1 autoconnect trigger value
(config)>
where value is one of:
n
always
n
data
n
dcd
n
destination
n
dsr
n
match
If match is selected:
i. Set the string that, when received, will trigger the connection:
(config)>serial port1 autoconnect match_string string
(config)>
ii. flush_string is enabled by default, which will discard the matched string from
data sent to the server. To disable:
(config)>serial port1 autoconnect flush_string false
(config)>
The default is always.
c. Set the option that initiates the connection:
(config)>serial port1 autoconnect conn_type value
(config)>
where value is one of:
n
ssh
n
tcp
n
telnet

Table of Contents

Related product manuals