E-VISION LASER 5000 SERIES USER MANUAL REV A JANUARY 2018
55
Select “Turn Windows features on or off” which will open the following window:
Tick the “Telnet Client” option, then press the “OK” button.
“RS232 by TELNET” information:
1. Telnet: TCP
2. Telnet port: 23
3. Telnet utility: Windows “TELNET.exe” (console mode)
4. To disconnect “RS232-by-Telnet” control: Close the Windows Telnet utility
5. Limitations for Telnet-Control:
1) There are less than 50 bytes available for each successive network payload for the Telnet-
Control application.
2) There are less than 26 bytes available for one complete RS232 command for Telnet-Control.
3) The minimum delay between sending RS232 commands via Telnet must be more than 200
(ms).
(N.B. In the Windows “TELNET.exe” utility, pressing the “Enter” key will also invoke a “Carriage-
Return” and a “New-Line” code to be generated.)