INSTALLATION
EPT023558 Issue 1 February 2016 4-3
SITE REQUIREMENTS
WARNING: Do not install the Blow applicator in hazardous
environments or in proximity to any flammable solvents
or gases.
The Blow applicators should be mounted securely in the desired location.
They should not be placed close to any heat source or in direct sunlight.
They should not be located in any hazardous environment, or in close
proximity to any flammable solvents or gases. The Blow applicators are not
suitable for outdoor use.
The Blow applicator is specified for operation in the following environmental
conditions:
Temperature
Standard unit (no accessories): +5 to +40ºC
Humidity
Standard unit (no accessories): 20% to 85% non-condensing
PRE-INSTALLATION
Please consider the optimal installation before you start with the work:
• Correct height.
• Position and orientation.
• Conveyor direction.
• Operator side etc.
Note: Consider necessary access for cleaning, label changes and routine
maintenance.
Read the bill of materials. Discuss these issues with the operators
responsible for the equipment.
INSTALLATION
The installation consists of three parts:
• Mounting the machine.
• Connecting the compressed air supply.
• Connecting power supply, I/O signals etc.
All three parts are described on the following pages.
CAUTION: Setup and configuration of the machine must be made by
skilled personnel.