INSTALLATION
4-12 EPT023558 Issue 1 February 2016
Connect an external load to the relay outputs (example)
JP2 - Reference voltage jumper
REF1 = Jumper in right position
The same reference voltage (connected to pin 29 or pin 40) is used in all
relays.
REF2 = Jumper in left position
The reference voltage connected to pin 29 is used in relays RE1-RE5. The
reference voltage connected to pin 40 is used in relays RE6-RE10.