INSTALLATION
EPT023558 Issue 1 February 2016 4-5
COMPRESSED AIR CONNECTION
The Blow applicator requires compressed air supplied with a pressure of 6
bar.
Note: The internal working pressure of the cylinders has been reduced
for safety reasons. It is highly recommended to avoid using a
higher pressure than necessary.
The Blow applicator have air regulators fitted as standard. However, it is still
very important that the air pressure does not vary too much as this will
often affect the accuracy when applying the label. Use a 10mm air tube.
ELECTRICAL AND COMMUNICATION
CONNECTIONS
The electrical feed can be from 110-240 V.
External devices, such as PLCs, Sensors and Scanners, etc are connected
using the terminal blocks, see illustrations. The terminal blocks contain
+24V and 0V to supply external product detectors, sensors, etc.
1
2 3 4 5 6 7 8 9 10 11 12
(1) Power On/Off switch
(2) Fuses Line & Neutral
(3) Mains plug
(4) Printer cable inlet
(5) Cable glands for sensors,
etc.
(6) USB type 2.0
(7) CH1 - RS232
(8) CH2 - RS232
(9) Applicator cable inlet
(10) Beacon cable inlet
(11) Sensor, PLC inputs/output
etc.
(12) Ethernet (WLAN optional)