INSTALLATION
EPT023558 Issue 1 February 2016 4-9
Supply voltage - Terminal blocks CN5 & CN6
The terminal blocks CN5 and CN6 contain +24V and 0V to supply external
product detectors, sensors etc.
External inputs - Terminal blocks CN3
The CN3 terminal block provides input connections for product detectors,
sensors etc.
Note: All Inputs are configurable. Standard as above.
Connect sensors to ACC inputs
Note: All photocells must be PNP photocells.
Pin Input Function Comments
19 IX1 Print label Standard print input (Photocell or
similar)
29 IX2 Reprint label
21 IX3 Apply 1 Standard apply input (Photocell or
similar)
22 IX4 Apply 2 The configuration of the user
defined inputs is made in the Setup
program or on the PCU front panel.
A configuration, based on the
applicator used and information
from customer, is in most cases
already done at delivery.
23 IX5 User defined
24 IX6 User defined
25 IX7 User defined
26 IX8 User defined
28 IX9 User defined
28 IX10 User defined