EasyManua.ls Logo

Dormakaba ED900 - Technical Data; ED900 Technical Data

Dormakaba ED900
124 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
ED900 02-202008125330
dormakaba ED900 Installation Instructions – Double egress door Chapter 6
Technical data
Maximum wire size
Connector plug
screw size
 AWG
/”
Door
status
X
,,
Sr parameter
Door closed
Door open
Door closed, locked
Com, N.O., N.C.
contacts
.. Integrated functions.
Hold open time:
Automatic opening
dd parameter  to  s
NIght / bank dn parameter  to  s
Manual opening
do parameter  to  s
Door blocking
behavior
hd parameter
Automatic, manual
door modes
Electric strike
delayed opening for
locking mechanism
Ud parameter  to  s
Locking
device
feedback
X
, 
Motor lock
Wind load control,
maximum
Fo, Fc parameters
. lb f
 N
Voltage independent
braking circuit
Chapter 
Adjustable with
potentiometer
LED status indicators
Chapter 
Green
Red
Yellow
 Vdc power
Error codes
Service interval
Program and Exit
Only switches
Chapter 
Auto, Close, Open
Exit only; Off, On
User interface Chapter 
 button keypad,
 digit display
Firmware update Appendix C Firmware update
TMP, temperature
management program Overload protection
IDC, initial drive control
Driving phase optimization
Cycle counter
CC parameter  to ,,
Power assist function
hA, hF, hS
parameters
Drive support for
manual opening of
door
Push & go function PG parameter
Auto opening of
door at ° open
. ED Technical data
.. Required operating conditions.
Ambient temperature  to  °F
Suitable for dry
rooms only
Relative air humidity:
% maximum, non-condensing
Power supply
 Vac ±%, / Hz
. A maximum
Branch circuit
protection (provided
by others)
 A maximum,
dedicated branch circuit
Protection class NEMA 
Power wiring:
black, white, bare
copper (ground)
 AWG
maximum
Operating noise Maximum  db(A)
.. General specifications.
Operator dimensions
(W x H x D)
" standard cover
" x  / x  /",
[ x  x  mm]
Operator weight . lb [ kg]
Maximum door
opening angle
 to ° depending on installation type
.. Inputs
Maximum wire size
Connector plug
screw size
 AWG
/”
Activation
inputs
X* Interior, exterior N. O. contact
Safety
sensors
X
Swing, approach
sides
Night-bank
(intercom
system)
X
,
a
- Vdc/Vac +%
Night-bank
(key switch)
X
, 
d parameter
Configure for N.O.
or N.C. contact
Deactivation
of drive
function
X
, a
d parameter
Configure for N.O.
or N.C. contact
.. Outputs
TIPS AND RECOMMENDATIONS
• *X: terminal board numbers, reference
Chapter , System accessories.
• Parameters, reference Chapter .

Table of Contents