82
ED900 02-202008125330
dormakaba ED900 Installation Instructions – Double egress door Chapter 26
Set track bumper stop
.. Set bumper stop position.
. Set program switch to OPEN.
. Door moves to set opening angle.
WARNING
Use caution when working in
proximity of door and track.
. Slide bumper and bumper stop toward
slide shoe until bumper is /" from
edge of slide shoe (Fig. ..).
. Tighten bumper stop M screw. Do not
overtighten.
CAUTION
Using program switch, close then
open door to verify gap between
bumper and slide shoe with door
at full open position.
. Set track bumper stop position
Fig. 26.1.2 Door at set opening angle
Fig. 26.1.3 Setting bumper stop location
Fig. 26.1.1 Program switch OPEN position
9 Slide shoe
12 Bumper
17 Bumper stop
13 MM5 x 13 FHMS
cross recessed
17
16
12
9
3/16” gap