EasyManua.ls Logo

Dormakaba ED900 - Page 33

Dormakaba ED900
124 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
33
ED900 02-202008125330
dormakaba ED900 Installation Instructions – Double egress door Chapter 13
Fig. 13.2.2 Assembly on hinge side, pull version with slide channel CPD and short pivot pin
Axle extension ED A B C D
Inches mm Inches mm Inches mm Inches mm
Standard ●  /   /  /   / 
/" [] ●   /   /   / 
 /" [] ●  /   /   /   / 
 /" [] ●  /   /   /   / 
B
D
A
C
Reveal depth maximum 2 3/8” [60]
Upper edge door
Upper edge door
Space for cable feed
5 7/8”
[150]
4 3/16”
[106]
1 3/4”
[45]
1 1/4”
[32]
3 15/16”
[100]
1 3/4”
[45]
4 3/4”
[120]
4 3/4”
[120]
4 3/4”
[120]
3 3/4”
[95]
7 11/16”
[195]
Ø 1/4”
[6,6]
2 1/2”
[63]
17 3/4”
[451]
1 1/4”
[31]
1/8”
[3]
When CPD lever is used, about 1 3/16” [30]
must be deducted from the actual reveal
depth when the parameter is set.

Table of Contents