29
There are 9 module tamper alarm reporting codes, one for each 4216 module that can be enrolled
onto the system.
There are 12 module tamper alarm reporting codes, one for each 4204 module that can be
enrolled onto the system.
Reporting Codes for the restoral of a modules tamper.
There are 8 keypad tamper restoral reporting codes, one for each keypad that can be enrolled
onto the system.
There is an RS-232 tamper restoral reporting code.
There are 7 reporting codes for tamper restorals on 4108, 4116 and 4164 zone expansion modules.
There are 9 tamper restoral reporting codes, one for each 4216 module that can be enrolled onto
the system.
There are 12 module tamper restoral reporting codes, one for each 4204 module that can be
enrolled onto the system.
[F] [A] [P] Keys Reporting Codes for [F]ire, [A]uxiliary, [P]anic key alarms, [F]ire, [A]uxiliary,
[P]anic key restoral and Duress Reporting Codes.
Reporting Codes for Closings by Access Codes. There are 128 reporting codes, one for each
access code.
Miscellaneous Reporting Codes for Closings. These 5 reporting codes are for Quick Arm, Partial
Closing, Auto Arm Closing, Auto Arm Abort and Keypad Lockout.
• Quick Arm - See [Q][0] user function in the system manual.
• Partial Closing - If a partition auto-arms, and some zones were open, the system will force arm
itself, bypass the open zones and send the partial closing reporting code to the monitoring
station along with the alarm reporting codes of the zones that are open. Also, if zones were
manually bypassed, the partial closing reporting code will be transmitted.
• Auto Arm Abort - If the autoarming is aborted with or without an access code, this reporting
code will be sent.
• Auto Arm Closing - When the system Auto-arms, the panel will send the autoarm reporting
code to the monitoring station. See Autoarm [Q][6] functions in the System Manual.
• Keypad Lockout - If too many incorrect access codes (see “TOTAL BAD CODES” under
Keypad Lockout Options for programming the number of incorrect code entries) are entered,
the keypad will lock up, preventing anyone from attempting to enter any more access codes.
When keypad lockout occurs, the keypad lockout reporting code is sent to the monitoring
station.
This code will be sent when the partition is armed. The system account code is sent followed •by
the programmed reporting code. If there is a user closing reporting code programmed it will also
be sent. This is to allow identification of the partition which armed when only one account code is
used for each of the Partitions and System Account codes. The user is identified with the closing
reporting code and the partition is identified with the Partition Close Reporting Code.
Note: During a Closing Suppression window the Partition Close reporting code will not be
sent.
SYSTEM AREA
COMMUNICATOR
REPORTING CODES
PC4216 16 O/P
(3)
PC4204 4 O/P
(4)
MOD TAMP RESTORE
(05)
LCD4500 KEYPADS
(0)
PC4400 RS-232
(1)
PC41XX ZONE EXP
(2)
PC4216 16 O/P
(3)
CLOSINGS
(13)
PC4204 4 O/P
(4)
[F][A][P] KEYS
(12)
MISC CLOSINGS
(14)
PARTITION CLOSE
(15)