30
SYSTEM AREA
COMMUNICATOR
REPORTING CODES
Reporting Codes for openings by Access Codes. There are 128 reporting codes, one for each
access code.
Miscellaneous Reporting Code for Openings.
Opening After Alarm - This reporting code will be sent to the monitoring station when the system
is disarmed, and there was an alarm while the partition was armed.
Opening Automatic - This reporting code will be sent any time an auto disarm schedule occurs
that disarms the partition.
Note: During an Opening Suppression schedule the Opening Automatic reporting code will
only be sent if there are alarms in memory.
This code will be sent when the partition is disarmed. The system account code is sent followed
by the programmed reporting code. If there is a user opening reporting code programmed it will
also be sent. This is to allow identification of the partition which disarmed when only one account
code is used for each of the Partitions and System Account codes. The user is identified with the
opening reporting code and the partition is identified with the Partition Open Reporting Code.
Note: During an Open Suppression Window the Partition Open reporting code will not be
sent unless there was an alarm during the armed period for that partition.
System Maintenance Reporting Codes. There are 19 reporting codes dealing with the operation
and maintenance of the system. The reporting codes are:
Battery Trouble and Battery Restoral - If the battery voltage on the PC4010 main panel is
weak, disconnected or if the battery fuse fails, a battery trouble occurs, and the battery trouble
reporting code is sent. When the battery voltage and fuse are restored, the battery restoral
code is sent. See Battery Trouble under Trouble Display [Q][2] in the System Manual.
AC Line Trouble and AC Line Restoral - If the incoming AC voltage to the AC terminals fails,
an AC trouble occurs and the AC trouble reporting code is sent to the monitoring station after
the AC Fail Tx Delay has elapsed (see “AC FAIL TX DELAY”). When the incoming AC is
restored, the AC restoral reporting code is sent to the monitoring station. See AC Trouble under
Trouble Display [Q][2] in the System Manual.
Main Bell Trouble and Main Bell Restoral - If a bell trouble occurs, either from the bell fuse
failure or the open bell terminals, the Main Bell Trouble reporting code will be sent to the
monitoring station. When the trouble condition is restored, the Main Bell Restoral reporting code
will be transmitted.
Main Aux Trouble and Main Aux Restoral - If an auxiliary voltage supply trouble occurs, the
Main Aux Trouble reporting code is transmitted, and when the auxiliary voltage supply is
restored, the Main Aux Restoral code is transmitted.
COMBUS Trouble and COMBUS Restoral - When the main panel losses communication with a
module, the COMBUS Trouble reporting code will be transmitted, and when communications
resume the COMBUS Restoral reporting code will be sent.
TLM Failure - If the Links unit is being used, a TLM reporting code will be sent through the
Links when a TLM trouble occurs. DO NOT PROGRAM THIS REPORTING CODE IF THE
LINKS MODULE IS NOT BEING USED.
TLM Restoral - If there is a telephone line monitoring trouble, the PC4010 will not be able to
communicate with the monitoring station until the telephone line is restored, then the TLM
Restoral reporting code will be sent.
TLM Fail Line 2 - If the LINKS unit is being used, a TLM reporting code will be sent through the
LINKS when a TLM trouble occurs. DO NOT PROGRAM THIS REPORTING CODE IF THE
LINKS MODULE IS NOT BEING USED.
TLM Restoral Line 2 - If there is a Telephone Line Monitoring Trouble, when the trouble
restores the panel will transmit the programmed reporting code reporting code.
FTC Restoral - If a failure to communicate trouble occurs, where the PC4010 could not get
through to the monitoring station, the next time the panel attempts to communicate and is
successful, it will also transmit the FTC restoral reporting code.
Periodic Test - This is the reporting code that is sent to the monitoring station to test
communications.
Buf Near Full - This reporting code is sent only if a printer is not being used, or the printer is off
line for 450 events.
OPENINGS
(16)
MISC OPENINGS
(17)
PARTITION OPEN
(18)
SYSTEM MAINT
(19)