7.1.3 Parameter List for the Operator Level of the DA220C Controls
Parameter Setting range Preset
No. Abbr. Designation/Function min max 100R
000 c2 Beginning bartack stitches-forwards 0 254 2
001 c1 Beginning bartack stitches-reverse 0 254 4
002 c3 End bartack stitches-reverse 0 254 3
003 c4 End bartack stitches-forwards 0 254 3
004 LS Number of light barrier compensation 0 254 4
stitches at long sewing length
005 LSF Number of stitches of the light barrier 0 254 0
filter for knit goods
006 LSn Number of seams to be ended with 0 15 1
the light barrier.
007 Stc Number of stitches in the automatically 0 254 10
conducted seam run
008 -F- Assigning a function to key 9 1 5 2
(in the V820 control panel)
1 = Softstart ON/OFF
2 = Fancy-stitch bartack ON/OFF
3 = Stroke adjustment
locking = ON / with keys = OFF
4 = Needle cooling ON/OFF 1 5 2
009 LS Light barrier ON/OFF 0 1 0
010 cLS Number of light barrier compensation 0 254 8
stitches at short sewing length
013 FA Thread trimmer ON/OFF 0 1 1
014 FW Thread wiper ON/OFF 0 1 0
015 StS Stitch counting ON/OFF 0 1 0
080 Sav Number of stitches-Beginning 0 254 3
fancy-stitch bartack-forwards
081 SAr Number of stitches-Beginning 0 254 3
fancy-stitch bartack-reverse
082 SEr Number of stitches-End fancy-stitch 0 254 3
bartack-forwards
083 SEv Number of stitches-End fancy-stitch 0 254 3
bartack-reverse