8.2.4 Changing Parameters at the Operator Level (A) 
The parameter values at the operator level (see Parameter List 8.2.5) can be changed
as follows.
–
Turn the mains switch on, do not operate the pedal.
–
The "Manual Sewing" work mode is active (the LED in the key 5 (P/M)) is dark).
–
Press the 6 (T/E) key, the LED is lit, sewing is no longer possible.
–
The first parameter at the operator level is shown in the display.
Example:
NumberMeaning Change via:
1 Number of forward stitches in the beginning bartack
3 Number of reverse stitches in the beginning bartack
5 Number of reverse stitches in the end bartack
7 Number of forward stitches in the end bartack
10 Parameter number (hundreds) P+ or P- key
11 Parameter number (tens) S+ or S- key
12 Parameter number (ones) S+ or S- key
14-16 Parameter value L+ or L- key
–
The parameter value can be changed with the L+ or L- key
–
The parameter number can be changed with the P+ or P- key (hundreds) or with
the S+ or S- key (tens and ones).
–
Press the 6 (T/E) key, the setting is saved, the operator level A is exited, the LED is
dark and sewing is possible again.
8.2.5 Parameter List at the Operator Level (A)
Parameter Setting RangePreset
No. Abbr. Designation/Function min max 100R
111 LS Light barrier compensation stitches 1 255 6
112 LS Number of stitches to the light barrier mark  0 255 0
by knitted goods
116 SANL Number of softstart stitches 0 255 2
148 AR Beginning bartack-double = I, single = II I II I
149 ER End bartack-double = I, single = II I II I
450 LS/STL Light barrier compensation stitches by short  1 255 6
sewing length 
523 RIE/ Change-over fancy-stitch bartack = I,  I II II
ZRIE normal bartack = II
64