8.2.10 Master Reset with the OC-TOP Control Panel
All parameter values changed in relation to the preset values are reset to the preset
values by a master reset. 
ATTENTION!
At a master reset several parameters such as e.g.
<700-707>
 (needle position), 
<799> (
selected machine
class) and
 <800>
 ( (motor direction of rotation) are not
reset. 
After a master reset all machine-specific parameters
must be set as per the parameter sheet again. See
Chapter 8.2.9.
Preparing the master reset 
–
Turn the main switch off.
–
Step the pedal completely forward and hold in this position.
–
Press the keys  P+ or P-, S+ or S- and L+ or L- at the same time and hold down.
–
Turn the main switch on.
–
Release the the three keys and bring the pedal into base position.
–
The display shows:
Conducting a master reset 
–
Press the P+ key below the "
Y
" (yes) indicator.
–
The master reset is initiated. If the master reset is not to be carried out, then the L+
key below the  "
N
" (no) indicator must be pressed.
–
The display briefly shows:
Then the display briefly shows the initialization display e.g.:
and then the display appropriate to the selected work mode.