3 Tests and Diagnostics
PORTÉGÉ X30W-J, dynabook V*/VZ*/VC* Series Maintenance Manual (960-941) [CONFIDENTIAL] 3-15
Subtest 5 [Specify Address Test]
First, specifying of the address of the start LBA, the data length and test data for
writing (Dword) is needed for this test. Then this test writes the specified test data to
the specified address and read them to compare.
If any errors occur at comparing, this test displays the message “
Compare error” and
writes the information to the text file (errorlog.txt) as an error log.
As for the details of the error log, refer to 3.12 Log utility.