3 Tests and Diagnostics
PORTÉGÉ X30W-J, dynabook V*/VZ*/VC* Series Maintenance Manual (960-941) [CONFIDENTIAL] 3-21
3.12 Log Utility
This function logs error information generated during the tests and stores the results in USB
memory.
(file name: errorlog.txt)
To execute the Log Utility, select LOG Utility from the test program menu (Top Menu),
and press Enter. The following screen will appear.
Display examples
T-Name Pass Sts Address Write Read
HDD_001_12345678_1234_1234567812345678_00000000_55555555
RAM_001_12345678_1234_1000007812345678_00000000_55555555
T-NAME..... Test name
(Test name example)
RAM_01.....Main Memory Test
HDD_01.....Sequential Read Test
HDD_02.....Partial Read Test
HDD_03.....Address Jump Test
HDD_04.....Address uniqueness Test
HDD_05.....Specify Address Test
BAT_01.....Battery Charge Test
Pass..... Pass count which the error occurred
Sts..... . Status
(Value)
00FF..... Data compare error (Memory Test/HDD Test)
00E0.....Data Not Found(Memory Test)
0002..... Protocol error (Memory Test/HDD Test)
Address… AddressMemory Test/HDD TestLBA No.
Write..... ... Write valueMemory Test/HDD Test
Read.... ...... Read valueMemory Test/HDD Test/ Battery Charge Test
To clear the log information, press C. To back to the main menu screen, press ENTER.