4 Replacement Procedures 4.19 LCD/CAMERA MODULE
4-84 [CONFIDENTIAL] PORTÉGÉ X30W-J, dynabook V*/VZ*/VC* Series Maintenance Manual (960-941)
9. Stick the INSU SQUARE in place.
10. Set the LCD UNIT on the LCD COVER ASSY in place.
11. Connect the SENSOR HARNESS to the connector CN9860 on the 3AXIS SENSOR
BOARD.
12. Set the 3AXIS SENSOR BOARD to the LCD COVER ASSY in place.
NOTE: When setting the 3AXIS SENSOR BOARD, do not touch the IC portion of the
3AXIS SENSOR BOARD.
13. Confirm that the SHUTTER SWITCH moves properly and move it open position.
14. Set the LCD LOW CAP ASSY to the LCD COVER ASSY while engaging the
latches.
15. Insert the LCD HARNESS into the HINGE L ASSY.
16. Set the HINGE L ASSY to the LCD COVER ASSY and secure it with the following
screws.
M2.52.5C S-THIN HEAD screw 2
17. Insert the CAMERA HARNESS into the HINGE R ASSY.
18. Set the HINGE R ASSY to the LCD COVER ASSY and secure it with the following
screws.
M2.52.5C S-THIN HEAD screw 2
19. Peel off the separator and set the HINGE CAP L ASSY to the LCD COVER ASSY
while engaging the latches.
20. Peel off the separator and set the HINGE CAP R ASSY to the LCD COVER ASSY
while engaging the latches.