46 GBK60348: Issue 3
Wizard to correct the problem. For more information, see Remote compatibility list
(4.1.3).
If a Master Remote is connected to a Power Module that it has been connected
to before, in some cases the Remote may not show the SBM Selection Sequence.
Instead, the Remote will copy its settings into the Power Module automatically*.
This also happens when the Remote has since been reprogrammed with the
Wizard. For more information, see SBM Connection Memory (4.1.2).
*After the settings have been copied into the Power Module, Flash Code 1 is shown
on the Remote to indicate that the system has just been programmed. Turn the
power off, wait 10 seconds, and turn the power back on to activate the settings.
4.1.2 SBM Connection Memory
If a Master Remote is connected to a Power Module that it has been connected to
before, in some cases the Remote will not show the SBM Selection Sequence. Instead,
the Remote will copy its settings into the Power Module automatically.
The Master Remote determines which Power Module it was last connected to with the
System Configuration ID (SCID). The Master Remote and Power Module both have a SCID.
If both modules have the same SCID, the SBM Selection Sequence will not be shown.
If the Master Remote copies its settings into the Power Module, it copies its own
SCID into the Power Module as well. As a result, both modules have the same
SCID, the SCID of the Master Remote.
If the Power Module copies its settings into the Master Remote, the SCID of the
Master Remote is changed, and the new SCID is copied back into the SCID of the
Power Module. As a result, both modules have the same, newly created, SCID.
Programming the system with the Wizard does not change the SCID in either
module.
4.1.3 Remote compatibility list
Not all DX2 Remotes accept the programs from other DX2 remotes.
All REM55x programs*. No REM42x programs.
All REM55x programs*. No REM42x programs.
All REM42x programs. No REM55x programs.
Only REM421 programs (REM420 programs contain lighting).
*Please note that REM55x programs in DX mode (CLAM) and DX2 mode (DX2-ACT)
will both be written to any REM55x without any problem. However, if a DX2 mode
program is written to a REM55x that is connected to a CLAM, or a DX mode program
is written to a REM55x that is connected to a DX2-ACT module, actuator functionality
will be disabled.