MAINTENANCE, SERVICE AND FAULT FINDING
25364 Issue 8 March 2018 4-51
1140 Unreferenced Macro
Output variable
A macro output variable is inserted into
a field (Text field), but is never
calculated by any macro.
Check the macro and the macro output
variable for any inconsistency.
(You can't have a macro output
variable on its own; it needs a macro to
calculate its value).
1141 Macro Out Variable
already ref.
A macro output variable can only be
updated by one macro.
This error is raised if multiple macros
try to access the same macro output
variable.
1142 Read only destination
var.
The destination variable is read only.
1143 Too Few Parameters The function used needs more
parameters
1144 Too Many Parameters The function used needs fewer
parameters
1145 Parentheses Ensure that placement of parentheses
in the macro is correct.
1146 Item description not
found
Ensure that the “Item Descriptions”
used in the macro refer to an actual
element in the design.
1148 Redefinition User is trying to redefine a variable.
Please verify variable naming.
1149 Macro out expected A variable of type “Macro output” was
expected as destination. Check syntax
and destination variable.
1170 Database File not
found
The database file could not be found.
Please check the filename.
Usually this can happen if the design is
simply stored by the design software
on a network drive.
1171 Database Key not
found
The key was not found. Check the
database and / or the key.
1172 CodePage file not
found
The codepage specified by the variable
could not be found. Please check the
codepage selection.
1173 Interrupt Not
Initialised
A part of the printing software was not
started correctly. Restart unit.