DESCRIPTION AND INSTALLATION
25364 Issue 8 March 2018 2-11
MECHANICAL INSTALLATION
Installation Requirements
Ensure that the following services and control signals are available:
Notes: (1) Compact 32d, 32c and 53c Power: 120/240 VAC, 50/60Hz, 1.5A
(2) Communicator II Power: 115/230 VAC, 50/60Hz
(1) For Communicator II: Compressed Air: 2-5 Bar, dry, uncontaminated.
Note: For purity of supplied compressed air, Easyprint requires
compliance with Compressed air purity classes ISO 8573-1 6 3
2 : 2001.
(2) A print start signal; we recommend a volt-free contact which closes
when printing is required.
(3) Sufficient space for installation and operation.
(4) If using the printer in Continuous Mode, an encoder giving 12 (or a
multiple of 12) pulses per mm is required to monitor the substrate
speed. (This is included with the CM bracket.)
Brackets - Compact 32d, 32c and 53c
Notes: (1) For a list of the tools required, see the bracket instructions
provided with the bracket kit.
(2) For spares information, see www.easy-print.com
The bracket range covers widths of up to 900mm. The available flat-pack
variants are:
• Window bracket (for IM and CM versions)
Notes: (1) The CM version includes the encoder and CM axle assembly.
(2) The CM rubber roller assemblies are available in 100mm size
increments (305mm to 805mm) and must be ordered separately.
(3) The Quick Release (QR) Carrier Assembly (P/N EPT006141) is
available for mounting the printers directly onto Compact 32d,
32c and 53c flat pack window brackets (IM bracket EAS002706
and CM bracket EAS002717). Use this assembly in wash-down
environments or other situations where printers need to be
removed on a regular basis. The assembly has the same overall
dimensions as the standard printer carrier (P/N 5-0460258) and
can be swapped out on existing installations.
• Web positioning module
• Labeller bracket (IM only)