6 Parameters
DC1 Frequency Inverter 10/12 MN04020003Z-EN www.eaton.com 97
P-19 147 ✓ rw K1-Limit value (relay) 100.0
P-02 - 200.0 %
The adjustable limit value that is being used in connection with
settings 4 to 7 of P-18 and P-25
P-20
148 ✓ rw Fixed frequency FF1 / speed 1 0.0
P-10 = 0 → -P-02 - P-01 → Hz
P-10 > 0 → -P-02 - P-01 x 60 s → rpm (1/min)
0.00 Hz (P-02) up to the maximum frequency value (P-01).
Activation via digital inputs depending on parameters P-12 and P-15
P-21
149 ✓ rw Fixed frequency FF2 / speed 2 0.0
P-10 = 0 → -P-02 - P-01 → Hz
P-10 > 0 → -P-02 - P-01 x 60 s → rpm (1/min)
0.00 Hz (P-02) up to the maximum frequency value (P-01).
Activation via digital inputs depending on parameters P-12 and P-15
P-22
150 ✓ rw Fixed frequency FF3 / speed 3 0.0
P-10 = 0 → -P-02 - P-01 → Hz
P-10 > 0 → -P-02 - P-01 x 60 s → rpm (1/min)
0.00 Hz (P-02) up to the maximum frequency value (P-01).
Activation via digital inputs depending on parameters P-12 and P-15
P-23
151 ✓ rw Fixed frequency FF4 / speed 4 0.0
P-10 = 0 → -P-02 - P-01 → Hz
P-10 > 0 → -P-02 - P-01 x 60 s → rpm (1/min)
0.00 Hz (P-02) up to the maximum frequency value (P-01).
Activation via digital inputs depending on parameters P-12 and P-15
P-24
152 ✓ rw Second deceleration time (dec2) 0.0
0.1 - 25.0 s (→ Figure 81, page 135)
This parameter makes it possible to program an alternative decelera-
tion time, in the frequency inverter, that can be selected via digital
inputs (depending on the setting for P-15) or automatically in the event
of a mains power failure if P-05 = 2.
If the value is 0.00, the frequency inverter will coast all the way to a
stop.
PNU
ID Access rights Value Description DS
RUN ro/rw