Technical data
A352-03-880 Issue B
2Technical data
2.1 Operating and storage conditions
2.2 Performance
Ambient temperature range (operation) 12 ºC to 40 ºC
Normal surface temperature of the pump Can exceed 70 ºC under covers
Maximum humidity (operation) 90%
Ambient temperature range (storage) -30 ºC to 70 ºC
ES65 ES100 ES200 ES300 ES630
Maximum displacement
50 Hz electrical supply m
3
h 64.3 96 198 293 635
60 Hz electrical supply m
3
h 77.2 115 240 354 769
Maximum speed – Pneurop
50 Hz electrical supply m
3
h 59 90 190 275 575
60 Hz electrical supply m
3
h 70 105 225 320 674
At 1mb inlet pressure (50 Hz) m
3
h 40 52 134 171 308
At 1mb inlet pressure (60 Hz) m
3
h 48 62 161 205 370
Motor rotational speed
Refer to
rating
label
Refer to
rating
label
Refer to
rating
label
Refer to
rating
label
Refer to
rating
label
50 Hz electrical supply r.min
-1
60 Hz electrical supply r.min
-1
Ultimate vacuum
Without gas ballast
(Total pressure)
mbar
kPa
0.15
0.015
0.15
0.015
0.08
0.008
0.08
0.008
0.1
0.01
With full gas ballast mbar
kPa
1
0.1
2
0.2
1
0.1
2
0.2
1
0.1
Maximum outlet pressure
(At full pump throughput)
bar gauge
Pa
0.5
1.5x10
5
0.5
1.5x10
5
0.5
1.5x10
5
0.5
1.5x10
5
0.5
1.5x10
5
Maximum water vapour pumping
rate
50 Hz electrical supply kgh
-1
1.3 2.6 2.2 2.3 5.6
60 Hz electrical supply kgh
-1
1.6 4.3 2.8 3.0 8.1
Maximum gas ballast flow
(Purge) regulated supply
pressure 0.5 bar (7 PSI)
l/min 55 56 124 126 136