A352-03-880 Issue B
Page 34 © Edwards Limited 2015. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Service, spares and accessories
Please refer to the following maintenance manuals for spares identification:
A352-01-855 for ES65/100
A352-02-855 for ES200/300
A352-03-855 for ES630
7.4 Accessories
Three types of accessories are available for the ES pumps.
Table 14 presents a summary of the oil level and temperature sensors available for ES pumps. Detailed fitting
instructions are provided below.
Table 13 - Accessories function
Accessory Function Customer Connection
Oil level sensor Open circuit when oil level is low Unterminated conductors
120 ºC sensor Open circuit when temperature exceeds 120 ºC Terminals
PT100 temp sensor Resistance temperature sensor Unterminated conductors
Table 14 - Oil level and temperature sensors
Oil level sensor
Oil level sensor and
120 ºC sensor
Oil level sensor
and PT100
PT100 temperature
sensor
ES65/100 A352-66-810 A352-66-811 A352-66-812 A352-66-813
ES200/ES300 A352-77-810 A352-77-811 A352-77-812 A352-77-813
ES630 A352-88-810 A352-88-811 A352-88-812 A352-88-813