A352-03-880 Issue B
Page 46 © Edwards Limited 2015. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Service, spares and accessories
7.4.12 PT100 temperature sensor (ES630)
Figure 24 - ES630 PT100 temperature sensor
Fitting Instructions (refer also to Table 13).
1. Drain oil from pump.
2. Remove the blank plate (Figure 24, item 1) and seal.
3. Clean the area where the PT100 temperature sensor (2) will be fitted.
4. Carry out a visual check on the sealing face of both the pump and the PT100 temperature sensor.
5. Secure using fixings provided.
7.4.13 ITO100 Inlet Catchpot
The ITO Inlet Catchpot is used on vacuum processes where large quantities of vapour are produced. The catchpot
traps liquid that would otherwise condense in the pipelines and drain towards the pump. The catchpot is also suitable
for use on vacuum processes where froth or spray can go into the pump.
The mixture of gas and liquid droplets enters the inlet of the catchpot. The liquid collects in the base of the body
and the gas passes through the outlet into the pump.
The level of the trapped liquid can be viewed through the sight glass (Figure 25, item 1). Drain the trapped liquid
from the catchpot through the drain plug (2).
7.4.14 ITO300 Inlet Catchpot
Description as in Section 7.4.13.
Product Item Number
ES630 PT100 temperature sensor
o
A352-88-813
Product Item Number
ITO100 inlet catchpot
o
A441-02-000
Product Item Number
ITO300 inlet catchpot
o
A441-03-000