7.4.10 Oil level sensor and120 ºC sensor (ES630)
Figure 22 - ES630 oil level sensor and120 ºC sensor
Fitting Instructions (refer also to Table 13):
1. Drain oil from pump.
2. Remove the blank plate (Figure 22, item 1) and seal.
3. Clean the area where the oil level sensor (2) will be fitted.
4. Fit the 120 ºC sensor to the face of the oil level sensor (2) using fixings provided.
5. Carry out a visual check on the sealing face of both the pump and the oil level sensor.
6. Secure using fixings provided.
Product Item Number
ES630 oil level and 120 ºC sensor A352-88-811
1. Blank plate
2. Oil level sensor and 120 ºC sensor