SCU-350 Series Control Unit for Turbomolecular Pump
MT-21E-201-E
Page 22
3
INSTALLATION
3.8.1 STP connection cable
CAUTION
Use the STP connection cable that has a label affixed
The use of different cables may result in product damage.
Connect the receptacle (socket) side of the STP connection cable to the STP connector on the STP
pump and connect the plug (pin) side to "P.CONNECTOR CON2"on the SCU-350.
24.5
76.5
69.9
φ4044.7
φ16
SCU-350 side
STP pump side
1
45 pin (pin) 2
41 pin (socket) 3
41 pin (socket, L-Type connector)
Figure 15 - STP pump connection cable
STP-301/451
Series
1
2
3

Table of Contents