- AB620A5035
Activated. The speed is limited to a value that depends on the lift level configured.
The speed is limited in the range between the maximum speed (n2, parameter 111) for the minimum height, and
a high lift walking speed (n10, parameter 117) for the maximum lift.
7.15.1 Programming the measurement value of the poti
Call parameter 911.
Turn the adjustment wheel for the lift until the value displayed changes.
Then set the minimum height lift.
Confirm the change with the E button
Call parameter 912.
Turn the adjustment wheel for the lift until the value displayed changes.
Then set the maximal height lift.
Confirm the change with the E button
Call parameter 401.
Set a value of 1 to save the changes. Storage by pressing the P button twice with subsequent approximation
is not possible here
NOTE
If the values are outside the permitted range, fault message A11 will be emitted.
7.16 Speed Limitation n9
Function with or without control panel
When a key is pushed to which input function 33 is assigned, speed limitation n9 is activated. The speed is
controlled by the pedal up to the limit.
7.17 Thread trimming operation
Thread trimmer On/Off
Thread wiper On/Off
Function with control panel
Thread trimmer or thread wiper On/Off
When a V820 control panel is connected, the functions can also be switched on and off using key 5.