EasyManua.ls Logo

Efka AB620A5035 - Starting Characteristics; Actual Speed Display; Operating Hours Counter

Efka AB620A5035
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- AB620A5035
6.14 Starting Characteristics
Function with or without control panel
Parameters
Starting edge
(ALF)
220
The drive acceleration dynamics can be adapted to the sewing machine characteristic (light/heavy).
High setting value = high acceleration
With a high starting edge setting and, in addition, possibly high braking parameter values on a light machine, the
characteristic may appear coarse. In this case, one should try to optimize the settings.
6.15 Actual Speed Display
Function with control panel
Parameters
Display actual speed
(nIS)
139
If parameter 139 = 1, the V810/V820 display shows the following information:
V810
V820
During operation:
The actual speed
Example: 2350 revolutions per minute
2350
2350
At stop in the seam:
The stop indication
StoP
StoP
At standstill after trimming:
On the V810, indication of the type of control
On the V820, indication of the set maximum
speed and the type of control
Example: 4000 revolutions per minute and type of
control AB425S
Ab620A
4000 Ab620A
6.16 Operating hours counter
Function with or without control panel
Parameters
Acoustic signal (operating part)
Service routine for total operating hours
Service routine for operating hours before service
Input of operating hours before service
(AkS)
(Sr6)
(Sr7)
(Sr)
127
176
177
217
The integrated operating hours counter records the time of motor operation. Downtimes are not recorded. Time
recording accuracy is 1ms. There are two ways of operating hours counting.
1. Basic operating hours counting:
217 =0
Operational mode: Operating hours counting

Table of Contents

Related product manuals