Battery
This setting allows the user to identify if Batteries will be
used in the system and, if yes, the type of batteries (Lead-
Acid or Lithium-Ion).
Operate with No Battery
Step 1: Choose battery type first. When “no” begins
flashing, select Enter to operate with No Battery
Note: It is NOT recommended to operate without batteries
Operate with Lead-Acid Battery
Step 1: Choose battery type first. When “Lead-Acid
begins flashing, select Enter to operate with Lead-Acid
Batteries.
Step 2: Enter the Battery Capacity (Ah)
Operate with Lithium Battery
Step 1: Choose battery type first. When “Li-ion” begins
flashing, select Enter to operate with Lithium Batteries.
Step 2: Enter the Battery Brand
(e.g., 0=EG4, 2=Pylon, 6=LuxPower, 8=Dyness)
4
UPS Output
Voltage and
Frequency
This setting allows the user to
set the inverter output voltage
and frequency.
AC Output Voltage:
200VAC, 208VAC, 220VAC,
230VAC, 240VAC
Default: 240VAC
AC Output Frequency:
50Hz, 60Hz
Default: 60Hz
5
Buzzer Enable
This setting allows the user to
enable or disable the inverter
buzzer.
Inverter Buzzer:
Enable/Disable
Default: Enable

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EG4 LuxPowerTek 6000XP and is the answer not in the manual?

EG4 LuxPowerTek 6000XP Specifications

General IconGeneral
CategoryInverter
Rated Power6000W
Max DC Input Power7800W
Number of MPPT Trackers2
Battery Voltage48V
Max Charge/Discharge Current120A
Protection DegreeIP65
Frequency50/60Hz
ModelLuxPowerTek 6000XP
CommunicationRS485
Operating Temperature Range-25°C to 60°C
Protection FeaturesOver Voltage Protection, Over Temperature Protection
CoolingFan