E L A N H O M E S Y S T E M S
INSTALLATION MANUAL
© ELAN Home Systems 2009 • All rights reserved. Page 73
S86A
System Commands
BAS (Bass)
Description:
Sets Zone zz to bass xy.
Increment Zone zz bass.
Decrement Zone zz bass.
Has no effect if zone is off.
If sending 00, the + or - can be omitted.
Command:
&S86,BAS,zz,a<cr>
&S86,BAS,zz,xy<cr>
Query:
&S86,BAS,zz?<cr>
Reply:
&S86,BAS,zz,xy<cr>
Parameters:
<cr>:
carriage return: Hexadecimal 0x0D or Decimal 13
zz:
Zone: 01-24
a:
+ = Increments by 1 step of 2dB (plus symbol)
- = Decrements by 1 step of 2dB (minus symbol)
x:
+ Sets to positive number (plus symbol)
- Sets to negative number (minus symbol)