102
102 EN
EPIR3 User Manual v1.3
7.11. Monitoring staton
The system can be congured to report events to the monitoring station by transmitting data messages
to the monitoring station. The system connects to the monitoring station when the MS (Monitoring
Station) mode is enabled. When using the MS mode, the data messages transmitted to the monitoring
station (see 7.11.1. Data Messages - Events) will gain the highest priority for the delivery, therefore
based on the communication method (see 7.11.2. Communication), a constant and stable connection
with the monitoring station must be ensured. In case of connection failure, the system will attempt to
restore the connection and if the monitoring is unavailable for a lengthy period of time, the system
might consume a large amount of voice calls/data resulting in additional charges applied by the GSM
operator according to the cell phone service plan.
4-digit Account number (by default – 9999) must be set up on the system in order to identify the alarm
system unit by the monitoring station.
ATTENTION: The system will NOT send any data to the monitoring station while remote conguration,
remote rmware update or remote listening is in progress. However, during the remote conguration session,
rmware update process or remote listening process, the data messages will be queued up and transmit-
ted to the monitoring station after the remote conguration session, rmware update or remote listening
process is over.
ATTENTION: Phone calls to the preset user phone number in case of alarm are disabled by force when MS
mode is enabled.
NOTE: Additional charges may apply for voice calls/data trac based on your cell phone service plan when
using the MS mode.
7.11.1. Data Messages – Events
The conguration of data messages is based on Ademco Contact ID protocol. The data messages can
either be transmitted to the monitoring station alone or with duplication by SMS text message to
preset user phone number. For more details on system notications by SMS text message, please refer
to 7.9. System notications.
Seq. No. Contact ID®
Code
Event Description
1 1110 Fire alarm Transmitted in case a zone of Fire type is violated.
2 3110 Fire restore Transmitted in case a zone of Fire type is restored.