113
113EN
EPIR3 User Manual v1.3
7.13. How to reset the system to default settings
1. Unplug USB cable (if any)
2. Open EPIR3 enclosure.
3. Press and hold the RESET button.
4. Wait for the LED to ash quickly several times.
5. Power down EPIR3.
6. Power up EPIR3.
7. Conguration has been restored to default.
7.14. How to upgrade the rmware locally via USB connection
1. Disconnect the power supply and backup battery..
2. Open EPIR3 enclosure.
3. Connect EPIR3 to the PC via USB cable.
4. Press and hold the RESET button.
5. Connect the power supply.
6. Release the RESET button after the new window pops-up containing a .bin le. Otherwise open My Computer
and look for Boot Disk drive.
7. Delete the .bin le located in this drive.
8. Copy and paste in the very same window.
9. After the copying is done, power down EPIR3.
10. Unplug USB cable.
11. Power up EPIR3.
12. Firmware upgraded.
NOTE: Alternatively, boot mode for EPIR3 rmware upgrade can be activated using ELDES Conguration
Tool software.