EPIR3 User Manual v1.3
7.3. Automatic system arming/disarming
The system comes equipped with automatic arm/disarm based on the assigned scheduler (-s). When one
or more schedulers are assigned, the system will automatically arm/disarm on the specied weekdays
and time set up in the scheduler. The system allows to assign up to 8 dierent schedulers. Each scheduler
includes the following parameters:
• Action:
• Arm system
• Disarm system
• Sch. No – Determines scheduler number assigned to a certain action.
• Status – Determines scheduler status (enabled/disabled).
• Hour – Determines the point in time when the scheduler is to take eect in hours.
• Minutes – Determines the point in time when the scheduler is to cease to take eect in minutes.
• Mo/Tu/We/Th/Fr/Sa/Su – Determines day (-s) in the week when the scheduler is to be valid.
7.4. Zones
Detection devices such as motion detectors and door contacts are connected to the alarm system’s zone
terminals. Once connected, the associated zone’s parameters must be congured.
EPIR3 comes equipped with 1 wireless zone and 1 on-board zone. For more details regarding zone expansion,
please refer to section 7.4.2. Zone expansion.
EPIR3 zones are classied by 3 categories:
Zone category Description
Max. number of
zones per device
Max. number of
zones in total
On-board zones Built-in wired zones of EPIR3 alarm system. 2 2
Wireless zones Non-physical zones automatically created by
connected wireless devices.
4* 32**
Virtual zones Non-physical zones intended for Panic button
feature (alarm activation upon pressing the
button) on EWK1/EWK2 wireless keyfob. Virtual
zones can be manually created using ELDES
Conguration Tool software.
32*** 32***
* - Depends on the connected wireless device.
** - Available only if no virtual zones are present.
*** - Available only if no wireless zones are present.