EPIR3 User Manual v1.3
Function EKB3W command Value Range Comment Example
Activate/deacti-
vate Congura-
tion mode
INSTaaaa# 4-digit administrator password INST1470#
Turn OFF PGM
output/set PGM
output startup
state as OFF
61xx0# xx 01 - 32 PGM output number 61250#
Siren/Alarm Settings Siren/Alarm Settings
Set alarm
duration
10xx# xx 00 - 10 alarm duration in minutes 1005#
Disable Bell
Squawk
290# disable system arm/disarm indication by siren sound 290#
Enable Bell
Squawk
291# enable 2 short siren beeps when the system is armed; 1 long siren beep when
the system is disarmed
291#
Disable siren
activation in
case of wireless
signal loss with
wireless device
760# system will not activate siren if it loses wireless signal with a wireless device 760#
Enable siren
activation in
case of wireless
signal loss with
wireless device
761# system will activate siren if it loses wireless signal with a wireless device 761#
Notication Settings Notication Settings
Disable periodic
INFO SMS
110000# disable INFO SMS
Set periodic
INFO SMS
11xxyy# xx 01 - 23 set time (hours = xx) for periodic INFO SMS delivery or period in hours (if the
period = yy in days is set to 0)
110315#
yy 00 - 99
Disable call in
case of alarm
300# system will not call any preset user phone number in case of alarm 300#