Function EKB3W command Value Range Comment Example
Activate/deacti-
vate Congura-
tion mode
INSTaaaa# 4-digit administrator password INST1470#
Enable SMS
regarding mains
power supply
loss/restore
131# system will send SMS text message to all preset user phone numbers
regarding mains power supply loss/restore starting with User 1. if the SMS
text message is not delivered (SMS delivery report not received) within 20
seconds, the system will move to the next preset user phone number until the
SMS text message is delivered
131#
Disable SMS in
case of back-up
battery fault
190# system will not send SMS text message to any preset user phone number in
case of back-up battery fault
190#
Enable SMS in
case of back-up
battery fault
191# system will send SMS text message to all preset user phone numbers in case
of back-up battery fault starting with User 1. if the SMS text message is not
delivered (SMS delivery report not received) within 20 seconds, the system
will move to the next preset user phone number until the SMS text message
is delivered
191#
Disable SMS
delivery report
for all system
notications
380# disable SMS delivery report to verify the SMS delivery to user phone number
status
380#
Enable SMS
delivery report
for all system
notications
381# the system waits for the GSM provider to conrm the successful SMS text mes-
sage delivery. in case of no SMS delivery report within 20 seconds, the system
sends an SMS text message to the next preset user phone number
381#
Detector Sensitivity Level Settings Detector Sensitivity Level Settings
Set PIR detector
sensitivity level
79xx# xx 20 - 99 higher value = lower sensitivity level 7960#
GSM Audio Settings GSM Audio Settings
Set microphone
gain for remote
listening
64xx# xx 00 - 15 adjust built-in microphone sensitivity level 6410#
Set speaker
level
67xxx# xx 00 - 100 speaker level 6725#